Winter Production Precautions for EPS Foam Factory Equipment
During the winter, EPS foam line factories must take special measures to ensure equipment safety and production stability under low-temperature conditions. Below are the key precautions:
1. Insulation for External Equipment

Insulate exposed water pipes to prevent freezing.
Avoid short circuits or electric shocks caused by frozen outdoor electrical equipment.
2. On-Site Safety Management
Promptly clear standing water on production sites to prevent slipping and injuries caused by ice formation.
3. Protection for Cutting Machines, Pre-Expanders, and Molding Machines
Copper Pipes and Pressure Devices: Drain condensation from copper pipes, pressure transmitters, and gauges using compressed air.
Steam Pipelines and Valves: Remove condensation from steam pipelines and valves.
Vacuum Pumps: Unscrew the drain plug on the pump body to release internal water.
Supply Pipelines: Clear residual water from vacuum supply pipelines.
Cooling Systems: Use compressed air to clean residual water from cooling pipelines and vacuum pump supply lines to avoid damage from freezing.
4. Central Vacuum and Pump Protection
Condenser: Drain cooling water and condensation from the central vacuum condenser.
Vacuum Pumps and Water Pipes: Ensure all residual water in vacuum pumps and water pipes is removed.
5. Precautions for Restarting Equipment
Closely monitor pressure gauges and sensor readings during restart to confirm alignment with actual values.
Prevent equipment damage or personnel injury caused by pressure loss